Pressure Reducing Stations | 2 Stage High Flow Reducing Station
with Remote Actuation for Rocket Launch ApplicationDycon Valves for Cunico Corporation

Features

2 Stage High Flow Reducing Station

Outlet stop valve is actuated using 80 psig pneumatic actuator gives remote on/off operation.
Non-isolatable relief valve protects downstream system and pipe work.
Intermediate relief valve not required.
Cartridge principle allows full maintenance of all valves with block welded in situ.
Material selection provides good resistance to humid environment on site.
Instrumentation drillings removes requirement for substantial pipe work.

Specifications

Application: Remote Switch on/off of high flow supply of air or gas.
Design Pressure: 6000 psig (400 bar) at 100 F (38 C).
Temperature Range: -4 to 248 F (-20 to 120 C).
Max. Flow Rate: To Customer Specifications.
Relief valve blow-down 10% and accumulation 10%.
Outlet pressure ranges from 1Barg to 280Barg with 10% lockup and 10% droop.
Non-return valve cracking pressure 0.1Barg.
Switched non-return valve provides indication of relief valve operation.

Schematic Diagram of 2 Stage High Flow Reducing Station

Drawing No. Weight lbs
(Estimated)
Inlet Pipe Size Outlet Pipe Size Block Dimensions
Length, L Width, W Height, H
RRU 6010-RB/1 1000 40mm
(1
")
80mm
(3
")
475mm
18.7"
435mm
17"
335mm
13.2"